赴澳留學三大途徑任你選
赴澳留學三大途徑任你選
澳大利亞以其優良的教育質量、清新的自然環境以及和諧的社會環境,每年吸引眾多的學生赴澳留學。作為一個移民國家,移民也是一部分學生留學澳大利亞的重要原因。
banjia22
暱稱: banjia22
性別: 女
國家: 台灣
地區: 其他地區
«‹ October 2026 ›»
SMTWTFS
123
45678910
11121314151617
18192021222324
25262728293031
最新文章
•無痛植牙-注意力不集中...
•床墊價格-定制床墊免費...
•台中室內設計-上海優秀...
•大台中夾報-報社志願者...
•燙睫毛-台灣開放大陸人...
文章分類
•全部 (544)
•寵物花草 (2)
•醫療保健 (27)
•工作職場 (4)
•工業機械與家電 (81)
•生活資訊 (167)
•投資理財 (20)
•汽車 (5)
•服飾批發 (35)
•美食 (29)
•美容整形 (11)
•家政服務 (34)
•旅行住宿 (16)
•旅行住宿 (5)
•婚慶文化 (19)
•教育學習 (21)
•買房與租房 (3)
•搜尋行銷 (31)
•經濟金融 (13)
•電腦網絡 (12)
•徵信與徵信社 (8)
•未分類 (1)
訪客留言
最近三個月尚無任何留言
每月文章
日誌訂閱
尚未訂閱任何日誌
好友名單
尚無任何好友
網站連結
尚無任何連結
最近訪客
最近沒有訪客
日誌統計
文章總數: 544
留言總數: 3
今日人氣: 170
累積人氣: 7095
站內搜尋
RSS 訂閱
RSS Feed
2011 年 2 月 15 日  星期二   晴天


New self-lubricating plastic plain bearings used in the isol 分類: 生活資訊

New self-lubricating plastic plain bearings used in the isolation switch

 

First, the isolating switch is mainly used to power high-voltage power distribution equipment parts and the need to reliably isolate live parts to ensure the safety of maintenance work. Isolating switch is in the sub-location, contact between the insulation to meet the requirements and obvious disconnect from the mark; the combined position, capable of carrying currents under normal circuit and abnormal conditions within the specified time (eg short circuit), the The current switching equipment

Second, the working principle of isolating switch

All Changlu contact isolation switch in the air, with a clear break point, isolating switch is not interrupter device, it can not be used to cut off the load current or short-circuit current, or under high pressure, a strong arc off point and difficult to extinguish, and may even result in arc (relative to short-circuit or white), burning equipment, endangering personal safety, this is the so-called "negative Hela isolation switch" serious accident. Isolating switch can also be used for certain circuit switching operation to change the system operates. For example: In the double-bus circuit, isolating switch can be used to run the circuit to switch from one bus to another bus. It also can be used to operate small current circuit; aluminum spot welding

Third, the isolation switch the use of sliding bearing rotating parts

Disconnect switch blade contact is isolated division and movement control can rely on manual and electric completed, but it is in the rotating parts that are required in any case be able to runslide bearing smoothly, which requires all rotating parts of the bearings in the longer even after a pause of time to ensure that work; order to ensure that the process of annual maintenance isolation switch can be normal operation which requires all rotating parts of the sliding bearing to resist the high and low temperature all year round and when the end-capping cross even after failure the erosion resistance of various external factors, such as salt spray, acid rain, oxidation caused by corrosion, and so the failure of natural factors.

Fourth, self-lubricating plastic bearings wear resistance

CSB-EPB series of self-lubricating plastic bearing possesses excellent self-lubricating and wear resistance is mainly CSB companies to take advantage of the self-lubricating material modification technology, high-performance engineering plastics used in high-strength fiber material of the load increases and special grease reduces friction coefficient, thus increasing wear resistance of materials to extend the integrated plastic bearing life. High-performance engineering plastics as the base material used primarily as wear-resistant vector; reinforcing fibers to improve the bearing load and impact resistance; special grease reduces bearing friction coefficient from the self-lubrication;

Fifth, self-lubricating plastic plain bearings for the advantage of isolating switch

Self-lubricating plastic bearings CSB-EPB1 suitable for rated voltage 40.5KV ~ 252KV indoor and outdoor high-voltage isolation switch the rotating parts of machinery to ensure whether in manual or electric operation can be completed successfully under the "floodgates" and "closing" action .

The use of plastic bearing pressure isolation switch has the following advantages:

1, CSB-EPB1 the plastic bearings can work in a vacuum environment, so use this plastic bearing the high-voltage isolation switch is not installed height restrictions, at an altitude of 3,000 meters above the mountains to work;

2, plastic bearings CSB-EPB1 the long-term use temperature of -50 ℃ ~ +110 ℃; so the use of this high-voltage isolation switch plastic bearings are used in the cold either north or south can be hot work; can be more than 10mm thick of ice work.

3, plastic bearings CSB-EPB1 very little moisture absorption of only 0.05%; use the plastic bearing the high-voltage isolation switch, whether in rain or high humidity can be high and dry summer, completion of the normal rotation.
 






訪客留言 (返回 banjia22 的日誌)

訪客名稱:
電郵地址: (不會公開)
驗證碼:  按此更新驗證碼 (如看不清楚驗證碼請點擊圖片刷新)
俏俏話: (必需 登入 後才能使用此功能)
[ 開啟多功能編輯器 ]