How to choose inverter thin-film modules 分類: 未分類

 New Energy Co., Ltd., Guangdong Bao Wei not only provide customers with professional stent design for the total package provides turnkey photovoltaic power plant construction services, with professional knowledge and rich experience, Paul Wei inverter for supporting the selection of components and also can give constructive comments.

 

Since crystalline silicon cell module fill factor is high, the peak point of the inverter is easy to find, but amorphous silicon thin film battery pack is relatively low fill factor, IV curve is gentle, the inverter need to set the step voltage tracking MPPT to find the peak point.

 

Meanwhile amorphous silicon thin film batteries need negative ground, in order to discharge static electricity and prevent common mode voltage to ground exceeds the system voltage and the inhibition photovoltaic array panels on the distributed capacitance of the inverter control circuit common mode interference. So you must use an internal or external transformer isolation (including step-up transformer) for grid tie inverter, grounding lines need to add DC leakage protection device to protect the personal safety.

 

Negative ground is not grounding lightning protection components, but mainly to prevent static electricity, so you can use indirect grounding method, using a large value resistors indirectly grounded to avoid a direct cause and without grounding transformer-isolated inverter incompatibility problems . Since the grounding resistor through the actual current is very small, will not cause the inverter http://www.gridtiepowerinverteronline.com/ without transformer-isolated DC leakage alarm

 

Meanwhile earth circuit DC leakage protection settings can play a small role in protecting the safety of personnel. The only downside is indirectly grounded in the inhibition of cell panel distributed capacitance of the inverter reduces common mode interference aspect, and this problem can be reduced distributed capacitance (eg with no border component) and the inverter internal circuitry to improve noise immunity resolved, and now most of the inverter can be fit.